Watts to Amps Calculator
Circuits and cables are rated in amps, but appliances are labelled in watts. This converter bridges the two: enter the wattage and your voltage — 120 V in North America, 230–240 V in most of Europe, the UK and Australia, or 12/24 V for DC systems — plus the load's power factor, to get the current draw. The calculation assumes a single-phase supply and the power factor you enter (1.0 by default — correct for resistive loads such as heaters, and for all DC supplies). Motors and other inductive loads have a lower power factor and can draw more current than the PF 1.0 figure suggests, especially when starting.
Results
Your results will appear here. Fill in the form and press Calculate.
How this calculator works
For a single-phase load, current is power divided by voltage and by power factor: A = W ÷ (V × PF). With a power factor of 1.0 — resistive loads like heaters, and every DC circuit — that reduces to plain watts ÷ volts. The same 1,200 W heater draws 10 A on a 120 V circuit but only about 5.2 A at 230 V — which is why high-power appliances are less stressful on 230 V systems, and why a device's amp draw always has to be quoted together with its voltage.
AC vs DC. Power factor is an AC concept: it measures how far the current waveform drifts out of step with the voltage in inductive or capacitive loads. DC has no waveform and no drift, so DC current is always just watts ÷ volts — if you select a 12 V or 24 V supply, leave the power factor at 1.0. On AC, motors, compressors and other inductive loads run at a power factor below 1.0 (often 0.8–0.95), which raises their current draw above the simple figure — and they draw a starting surge well above their running amps on top of that.
One more caution: this calculator deliberately does not recommend breaker or circuit sizes. Breaker selection, cable sizing and how much of a circuit's rating a continuous load may use are set by your local electrical code and depend on the wiring and the installation, not just the load — if a result is anywhere near a circuit's rating, consult a qualified electrician before relying on it.
The formula
Worked example
A 1,200 W heater on a 120 V supply draws 1,200 ÷ 120 = 10 A at its power factor of 1.0. The same heater at 230 V draws only 1,200 ÷ 230 = 5.2 A. A 1,200 W motor at the same 120 V but with a power factor of 0.8 would draw 1,200 ÷ (120 × 0.8) = 12.5 A — which is exactly why the power-factor input exists. Two such heaters running at once would draw 20 A in total at 120 V — whether a particular circuit can safely supply that depends on its rating, its wiring and your local electrical code, which is a judgement for a qualified electrician, not for a calculator.
Frequently asked questions
How many amps is 1,000 watts?
At 120 V it is 8.3 A; at 230 V it is 4.3 A; at 12 V it is 83 A. There is no single answer without the voltage — that is the whole point of the formula.
Why does the same appliance draw fewer amps in Europe?
Because European mains voltage is roughly double North America's. Power is volts × amps, so doubling the voltage halves the current needed for the same wattage.
Does this work for three-phase power?
No — three-phase uses A = W ÷ (√3 × V × power factor). This calculator is for the single-phase supplies used in homes. For industrial three-phase equipment, use the manufacturer's plate figures.
Can I just add up the amps of everything on a circuit?
Adding running amps is a useful first check, but it is not the whole story: motors surge on start-up, and electrical codes limit how much of a circuit's rating continuous loads may use and how circuits must be protected. If your total is anywhere near the circuit's rating, have a qualified electrician measure the real draw with a clamp meter and advise you.