Air Conditioner Electricity Cost Calculator

Air conditioning is often the single biggest driver of a summer electricity bill. This calculator estimates your AC running cost from its power draw, how many hours a day it runs and its duty cycle — the share of that time the compressor is actually working hard.

Your details

The pre-filled rate is an example rate for the selected country, not a live official tariff. Check the unit rate on your own bill and edit it — your results use exactly the number you enter.

Rule of thumb: watts ≈ BTU ÷ 3.4 for a typical unit (an EER of about 3.4). Efficient inverter models draw less; old units draw more. Check the nameplate for your exact figure.

A fixed-speed compressor is either fully on or fully off. An inverter compressor slows down instead of switching off, so it averages less power while holding a temperature — this calculator models an inverter at 80% of the average draw of a fixed-speed unit at the same duty setting. That 80% is a modelling assumption, not a measurement: sizing, weather and the room itself move the real figure.

Once the room reaches temperature, the compressor eases off. 100% = full power the whole time (very hot days, older on/off units). 60–80% is typical; inverter units holding a steady temperature can be lower. However carefully you set these inputs, treat the result as an estimate — actual consumption varies with weather, room size, insulation and thermostat setting.

Results

Your results will appear here. Fill in the form and press Calculate.

How this calculator works

An air conditioner's nameplate wattage is its draw while the compressor runs at full load. In real use, the unit cycles: it cools hard until the thermostat is satisfied, then the compressor slows (inverter models) or switches off and on (fixed-speed models). The duty cycle captures that behaviour — at a 70% duty cycle, a 1,500 W unit behaves, on average, like a 1,050 W unit over the hours it is switched on.

Inverter vs fixed-speed. A fixed-speed compressor is binary: full power or nothing, so its average is set purely by how often it is on. An inverter compressor modulates — it slows down and sips power to hold the set temperature — so at the same duty-cycle setting this calculator models an inverter's average draw at 80% of a fixed-speed unit's. That 80% is an explicit modelling assumption, and you can bend it either way with the duty cycle: if your inverter cruises gently in a well-insulated room, a lower duty figure may fit better. A plug-in energy meter is the only way to know your unit's true average.

Cooling demand rises sharply with outdoor temperature, room size, insulation quality and how low you set the thermostat. Each degree lower on the thermostat typically adds a few percent to running time, which is why the duty-cycle input matters more than small differences in rated wattage.

The formula

Effective watts = rated watts × duty cycle %
kWh per day = effective watts × hours per day ÷ 1,000
Monthly cost = kWh per day × days per month × rate

Worked example

A 1,500 W split AC runs 8 hours a day for 30 days at a 70% duty cycle, with electricity at $0.17/kWh.

Energy per day = 1,500 × 8 × 0.70 ÷ 1,000 = 8.4 kWh. Monthly energy = 8.4 × 30 = 252 kWh. Monthly cost = 252 × $0.17 = $42.84. At a 100% duty cycle the same unit would use 360 kWh and cost $61.20 — the gap shows how much thermostat behaviour and insulation are worth.

Frequently asked questions

How many watts does a typical air conditioner use?

Small window units draw roughly 500–900 W, a 12,000 BTU mini-split around 1,000 W, an 18,000 BTU split around 1,500 W, and central systems 2,000–4,000 W. These are typical ranges — your nameplate figure is the accurate one.

What duty cycle should I use?

Use 100% for a unit that runs flat-out on very hot days or an old fixed-speed unit in a poorly insulated room. For a modern inverter unit maintaining temperature in a reasonably insulated room, 50–75% is a realistic band — and select the inverter unit type, which models its average draw at 80% of a fixed-speed unit at the same duty setting.

Does raising the thermostat really save much?

Yes. Setting 24–25 °C instead of 21–22 °C shortens compressor run time noticeably. Combined with the duty-cycle effect above, a few degrees can cut the monthly cost by a fifth or more.

Why is my AC bill higher than this estimate?

Common causes: the unit runs more hours than estimated, the duty cycle is close to 100% during a heatwave, filters are clogged, or the tariff has time-of-use peak pricing higher than the flat rate entered here.