How Much Electricity Does an Air Conditioner Use?

An air conditioner's electricity use depends on three things: how powerful it is, how many hours it runs, and how hard it has to work during those hours. Get those three right and you can predict a cooling bill closely. Get the third one wrong — as most rough estimates do — and you can be out by half.

Typical power draw by type

While the compressor is running at full load, most home units fall into these typical ranges:

TypeTypical cooling capacityTypical power draw
Small window unit5,000–8,000 BTU500–900 W
Large window unit10,000–14,000 BTU900–1,400 W
Mini-split (single room)9,000–12,000 BTU700–1,100 W
Split system (living area)18,000–24,000 BTU1,400–2,200 W
Central air (whole house)36,000–60,000 BTU2,000–4,000 W

These are ranges, not specifications — efficiency varies a lot between models. A rough conversion is watts ≈ BTU ÷ EER, and a typical EER is around 3.4 in the units used on many rating plates (equivalently, an EER of about 11–12 in imperial units). Your unit's nameplate or manual always wins over a table like this.

From watts to kWh: the duty cycle

The nameplate wattage is the draw at full load. Once the room reaches the set temperature, a fixed-speed unit's compressor switches off and on, and an inverter unit slows down. Over an evening, a unit switched on for 8 hours might do the equivalent of 5–6 hours of full-power work. That equivalent share is the duty cycle.

So a 1,500 W split running 8 hours a day at a 70% duty cycle uses 1,500 × 8 × 0.7 ÷ 1,000 ≈ 8.4 kWh per day — about 250 kWh over a 30-day month. In a heatwave, or in a sunny, poorly insulated room, the duty cycle climbs towards 100% and the same unit approaches 360 kWh a month.

Inverter units change the shape of that curve: instead of switching off, the compressor slows down, so an inverter holding a temperature draws a steadier, lower average than a fixed-speed unit cycling around the same setpoint. Our calculator models this with its unit-type setting — an inverter is averaged at 80% of a fixed-speed unit at the same duty setting. That is a modelling assumption, not a measurement; a plug-in energy meter settles the question for your own unit.

What pushes consumption up

Work out your own number

Find the wattage on the nameplate (or estimate it from BTU), count your real running hours for a week, and pick an honest duty cycle — 100% for the hottest weeks, 60–80% for typical inverter use. Our calculator does the arithmetic and prices it at your own tariff:

Try it: the Air Conditioner Electricity Cost Calculator turns watts, hours and duty cycle into a daily, monthly and yearly cost.

Figures in this guide are typical ranges for orientation. Your unit's rating plate and your meter are the authoritative sources for your home.